BRAC University Institutional Repository

Data processing through biosensors and development of simulation software in windows & RT-Linux

DSpace/Manakin Repository

Show simple item record

dc.contributor.author Razin, Kazi Mohammed
dc.contributor.author Hossain, Jonayet
dc.contributor.author Oyon, Mahmudul Hasan
dc.date.accessioned 2012-04-05T06:29:55Z
dc.date.available 2012-04-05T06:29:55Z
dc.date.issued 2012-04-05
dc.identifier.other ID 09221067
dc.identifier.other ID 09221060
dc.identifier.other ID 09221214
dc.identifier.uri http://hdl.handle.net/10361/1756
dc.description This thesis is submitted in a partial fulfillment of the requirement for the degree of Bachelor of Science in Electrical & Electronic Engineering en_US
dc.description.abstract Solving real life problems are often very time demanding due to the high sensitivity of the system such as biomedical devices which are actually used to get data to represent the critical state of a human or animal body. There are some important indicators of human health those include ECG, SPO2, Temperature and Blood pressure. By monitoring those indicators the current state of any human health is possible to determine and hence necessary steps can be taken. Therefore the Real Time monitoring of the health indicators signals is very important in Biomedical Engineering. In our approach we have experimentally proved and did the signal processing of important biomedical signals using Windows and Linux OS. For Linux we have used Red hat enterprise Linux 4 and RT Linux which are soft real time and hard real time operating system respectively. The data acquisition system of the signals has been done through a data acquisition Card and interfacing of the system to computer has been done both in Windows and Linux. We did it to make a comparison between the time dependencies of signals in different operating system under multitasking environment. So our objectives are to make a Real time signal processing systems and software for biomedical devices as well as to compare the time delay of the measurement system under 2 operating systems. We approached it by choosing three health indicators signals which are ECG, SPO2 and Temperature. en_US
dc.language.iso en en_US
dc.publisher Department of Electrical and Electronic Engineering, BRAC University
dc.title Data processing through biosensors and development of simulation software in windows & RT-Linux en_US