Rectangular microstrip patch antenna for biomedical application using ISM band
| bracu.type.group | Research Publications | |
| datacite.rights | Metadata Only | |
| dc.contributor.author | Ridoy, Prince Mahmud | |
| dc.contributor.author | Md.elme, Khan | |
| dc.contributor.author | Saha, Pranta | |
| dc.contributor.author | Hoque, Md. Jawad-Al-Mursalin | |
| dc.contributor.author | Tulka, Tasmin Kamal | |
| dc.contributor.author | Rahman, Md.Abdur | |
| dc.contributor.department | Department of Mathematics and Natural Sciences | |
| dc.date.accessioned | 2026-08-10T06:53:54Z | |
| dc.date.available | 2026-08-10T06:53:54Z | |
| dc.date.issued | 2025-06-21 | |
| dc.description.abstract | In this study, a microstrip patch antenna has been designed to detect cancer tumors which operates at the Industrial, Scientific, and Medical (ISM) band at 2.475 GHz. The antenna is a rectangular-shaped microstrip patch antenna that can be worn on the body and has a dimension of 75.16 × 58.34 × 1.56 mm3. Because of its small scale, it is ideal for on-body appliances. The antenna's dielectric layer is FR-4 lossy with a width of 1.5 mm, and the metallic patch and ground are copper, with each having a width of 0.03 mm. This antenna is designed and is simulated using the Microwave Studio CST software tool. The simulation results have been measured both for off-body and on-body, the return loss is -58.20dB and -25.43dB, and the measured efficiencies are 64.49% and 56.81%, respectively. | |
| dc.description.version | Published | |
| dc.format.extent | 6 Pages | |
| dc.identifier.citation | P. M. Ridoy, K. Md.Elme, P. Saha, M. J. -A. -M. Hoque, T. K. Tulka and M. A. Rahman, "Rectangular Microstrip Patch Antenna for Biomedical Application Using ISM Band," 2021 International Conference on Intelligent Technologies (CONIT), Hubli, India, 2021, pp. 1-6, doi: 10.1109/CONIT51480.2021.9498491. | |
| dc.identifier.doi | 10.1109/CONIT51480.2021.9498491 | |
| dc.identifier.issn | 978-172818583-5 | |
| dc.identifier.uri | https://hdl.handle.net/10361/28879 | |
| dc.language.iso | en_US | |
| dc.publisher | Institute of Electrical and Electronics Engineers Inc. | |
| dc.relation.uri | https://ieeexplore.ieee.org/document/9498491 | |
| dc.subject | Bio-medical applications | |
| dc.subject | CST-software | |
| dc.subject | ISM band | |
| dc.subject | Muscle phantom | |
| dc.subject | Rectangular-shaped | |
| dc.subject | Return-loss | |
| dc.subject.lcsh | Microstrip antennas. | |
| dc.subject.lcsh | Antennas (Electronics). | |
| dc.subject.lcsh | Cancer--Diagnosis. | |
| dc.subject.lcsh | Biomedical Engineering. | |
| dc.title | Rectangular microstrip patch antenna for biomedical application using ISM band | |
| dc.type | Conference Proceedings |