Effect of component unavailability on power distribution feeder reliability
| bracu.type.group | Research Publications | |
| datacite.rights | Metadata Only | |
| dc.contributor.author | Shaikat, Md Al Hasan | |
| dc.contributor.author | Roy, Bannay | |
| dc.contributor.author | Faruk, Md Fardaus Hasan | |
| dc.contributor.author | Srabonti, Tasnuva Meherin | |
| dc.contributor.author | Nazmul Huda, A.S. | |
| dc.contributor.department | Department of Electrical and Electronic Engineering | |
| dc.date.accessioned | 2026-08-22T03:45:57Z | |
| dc.date.available | 2026-08-22T03:45:57Z | |
| dc.date.issued | 2023-01-01 | |
| dc.description.abstract | Reliability of an electric power distribution feeder is affected by the availability of various components such as disconnecting switches, fuses and alternate supply. Depending on the restoration process of connected low voltage transformer, the outage duration can be changed. This paper presents the results of a range of cases to find the effect of unavailability of components on the feeder reliability. For this purpose, a simple distribution feeder from standard Roy Billinton Test System (RBTS) is selected as a test feeder. Analytical approach is used to evaluate the feeder reliability indices. A total of sixteen different distribution feeder design configurations are investigated to find the unavailability impact of individual and group of components. Both overhead and underground feeders are considered for comparison purposes. The results show that reliability of a distribution feeder is significantly decreased by the unavailability of components. | |
| dc.description.version | Published | |
| dc.format.extent | 6 Pages | |
| dc.identifier.citation | M. Al Hasan Shaikat, B. Roy, M. F. H. Faruk, T. M. Srabonti and A. S. N. Huda, "Effect of Component Unavailability on Power Distribution Feeder Reliability," 2023 6th International Conference on Electrical Information and Communication Technology (EICT), Khulna, Bangladesh, 2023, pp. 1-6, doi: 10.1109/EICT61409.2023.10427875. | |
| dc.identifier.doi | 10.1109/EICT61409.2023.10427875 | |
| dc.identifier.issn | 9798350370836 | |
| dc.identifier.other | 2-s2.0-85186744974 | |
| dc.identifier.uri | https://hdl.handle.net/10361/29409 | |
| dc.language.iso | en_US | |
| dc.publisher | Institute of Electrical and Electronics Engineers Inc. | |
| dc.relation.hasversion | 10.1109/EICT61409.2023.10427875 | |
| dc.relation.ispartof | 2023 6th International Conference on Electrical Information and Communication Technology Eict 2023 | |
| dc.relation.ispartofseries | 2023 6th International Conference on Electrical Information and Communication Technology Eict 2023 | |
| dc.relation.uri | https://ieeexplore.ieee.org/document/10427875 | |
| dc.subject | Low voltage | |
| dc.subject | Fuses | |
| dc.subject | Transformers | |
| dc.subject | Reliability engineering | |
| dc.subject | Meteorology | |
| dc.subject | Power distribution feeder | |
| dc.subject | Feeder configurations | |
| dc.subject.lcsh | Electric power distribution--Reliability. | |
| dc.title | Effect of component unavailability on power distribution feeder reliability | |
| dc.type | Conference Proceeding | |
| person.affiliation.name | BRAC University | |
| person.affiliation.name | BRAC University | |
| person.affiliation.name | BRAC University | |
| person.affiliation.name | BRAC University | |
| person.affiliation.name | BRAC University | |
| person.identifier.scopus-author-id | 57563318700 | |
| person.identifier.scopus-author-id | 58920421100 | |
| person.identifier.scopus-author-id | 58920645900 | |
| person.identifier.scopus-author-id | 58920513500 | |
| person.identifier.scopus-author-id | 55838920700 |