Show simple item record

dc.contributor.advisorRahman, Dr. Md. Mosaddequr
dc.contributor.authorBegum, Mohaimina
dc.date.accessioned2016-01-14T15:17:41Z
dc.date.available2016-01-14T15:17:41Z
dc.date.copyright2015
dc.date.issued2015-10
dc.identifier.otherID 10371003
dc.identifier.urihttp://hdl.handle.net/10361/4824
dc.descriptionThis thesis report is submitted in partial fulfillment of the requirements for the degree of Master of Electrical and Electronic Engineering, 2015.en_US
dc.descriptionCataloged from PDF version of thesis report.
dc.descriptionIncludes bibliographical references (page 47-48).
dc.description.abstractHardware configurable Single Channel Analyzer (SCA) is designed and developed to improve the performance and flexibility of the system compared with traditional approaches. In this work, a new technique has been introduced for changing the window between the Upper Level Detection (ULD) and the lower Level Detection (LLD) for SCA by a simple change in software, without any hardware modification. To check this technique, electric pulse generated from the detector conditioned by a preamplifier is fed to ADC through a processing circuit. When the ADC output value is higher than the LLD and lower than the ULD, then counter will count those values over a period of one minute and store the counting value in a register. Finally the stored counting values are given to LCD through other necessary circuits. In addition, maximum peak value, counts per minute and total counting value are also displayed on LCD. Associate firmware has been developed by Xilinx ISE Design suite 9.2 using VHDL code and tested on Xilinx Spartan 3E Starter board. This developed system may be effectively used for radiation monitoring of human body as well as environment.en_US
dc.description.statementofresponsibilityMohaimina Begum
dc.format.extent93 pages
dc.language.isoenen_US
dc.publisherBRAC Universityen_US
dc.rightsBRAC University Internship reports are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission.
dc.subjectElectrical and electronic engineeringen_US
dc.subjectSingle Channel Analyzer (SCA)en_US
dc.titleFPGA based Single Channel Analyzer (SCA) used for nuclear radiation counting systemen_US
dc.typeThesisen_US
dc.contributor.departmentDepartment of Electrical and Electronic Engineering, BRAC University
dc.description.degreeM. Electrical and Electronic Engineering


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record