Measurement and analysis of temperature dependent resistance of 𝑳𝒊𝒙𝑪𝒖0.5𝒁𝒏𝟎.𝟓−𝟐𝒙𝑭𝒆𝟐+𝒙𝑶4
View/ Open
Date
2023Publisher
Brac UniversityAuthor
Jajayare, MD.Jabar AlMetadata
Show full item recordAbstract
The DC electrical property of 𝑳𝒊𝒙𝑪𝒖0.5𝒁𝒏𝟎.𝟓−𝟐𝒙𝑭𝒆𝟐+𝒙𝑶4 (x=0.00, x=0.05, 0.10) samples
prepared by solid state reaction method was investigated. The samples were calcined at
800℃ and sintered at 1000℃ and 1050℃ respectively in air for 5 hours. The samples were
placed in an electric oven and the corresponding resistance and temperature measurement
were taken using 2 probe method by keithley 2450 and 6517b respectively. The resistance
was found to decrease as the value of x increased and also increasing temperature showed
semiconductor behaviour of the samples