An analytical assessment of GPL kit for field level detection of arsenic in water
Date
1999-07Publisher
BRAC Research and Evaluation Division (RED)Author
Hossain, Md. ZabedMetadata
Show full item recordCitation
Hossain, M. Z. (1999, July). An analytical assessment of GPL kit for field level detection of arsenic in water. Research Reports (1999): Social Studies, Vol – XXIV, 101–115.Abstract
An attempt was taken to evaluate the suitability of GPL kit for field level detection of
arsenic in water. The sources of variation in results of tests for arsenic determined by GPL
kit seemed to be use of different sets of apparatus, reagents and person to person handling
of the apparatus. Variation in results of tests due to use of different sets of the GPL kit was
more prominent (Standard deviation 76.524) than that of the reagents used and person to
person handling (Standard deviation 40). Among the three sources of variation person to
person handling of the kits bad the least effect on the test results. Results given by GPL
and NIPSOM kits did not differ qualitatively although differed quantitatively.