    Comparative load flow analysis of a 400/230 KV grid substation in Bangladesh

    Thumbnail
    View/Open
    16121128, 16321019, 16121019, 16121159_EEE.pdf (1.201Mb)
    Date
    2020-06
    Publisher
    Brac University
    Author
    Khan, Rahat
    Newaz, Abdullah Ibna
    Haque, Mohd Fahim
    Nafis, Nur Qutubul Alam
    Metadata
    Show full item record
    URI
    http://hdl.handle.net/10361/14893
    Abstract
    A load flow analysis study is performed to a 440/220kV substation using ETAP and DIgSILENT software. This report shows load flow results, and explains how we can use it to implement changes on the feeders that will ameliorate the voltage profile. The power flow study for this station will be performed on ETAP and DIgSILENT power factory. The acronym ETAP stands for Electrical Transient and Analysis Program. This two software were used as an extensive program for the modelling, simulation, and protection of electrical networks. They not only provide solutions to substation designs, but also specialize in generation, transmission, and distribution of power systems. The software relies on predictive simulation. This allows the user to perform analysis using real-time system parameters and may also simulate abnormal scenarios to predict equipment malfunctioning. It can be used as a preventive simulation, which allows the user to see any automated circuit breakers, relays, alarms and warnings. These alarms and warnings are based on events that could potentially occur and corrective action will be suggested. The results are always verified and analyzed against field results, real system measurements, and hand calculations. The one-line diagram of the electrical system in question is composed of several pieces of equipment, each with a specific function. All of the components for this substation are high-voltage components. Some of the most important components are the Generators, capacitor banks, transmission lines, buses, potential transformers, and current transformers. These will affect the design for the substation and the operation.
    Keywords
    Load flow analysis; 440/220kV substation; DIgSILENT; ETAP; Predictive simulation
     
    LC Subject Headings
    Electric power systems--Load dispatching
     
    Description
    This thesis is submitted in partial fulfillment of the requirements for the degree of Bachelor of Science in Electrical and Electronic Engineering, 2020.
     
    Cataloged from PDF version of thesis.
     
    Includes bibliographical references (pages 47-48).
    Department
    Department of Electrical and Electronic Engineering, Brac University
    Collections
    • Thesis & Report, BSc (Electrical and Electronic Engineering)

    Copyright © 2008-2019 Ayesha Abed Library, Brac University 
    Contact Us | Send Feedback
     

     

    Policy Guidelines

    • BracU Policy
    • Publisher Policy

    Browse

    All of BracU Institutional RepositoryCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    Copyright © 2008-2019 Ayesha Abed Library, Brac University 
    Contact Us | Send Feedback